MOBILE CALL
GSM Alarm System
Users Manual
Profile
For a better understanding of this product, please read this user
manual thoroughly before using it.
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - GSM Alarm System

MOBILE CALL GSM Alarm System User’s Manual Profile For a better understanding of this product, please read this user manual thoroughly before us

Pagina 2 - Contents

10 The remote controller can’t control the main unit after it’s deleted. In setup state, use keypad to input [21], then input the remote controller

Pagina 3

11 1) Change Operation Password Operation password is the password used to disarm or remote control. In setup status, use keypad to input

Pagina 4

12 digits [EE] of the minute, the two digits [FF] of the second, and finally enter [#] to confirm. You will hear a long beep and a voice

Pagina 5

13 Operating method: [XX][AA][BB][#] XX indicates: the address code 36, 37, 38 of the timely disarming AA indicates: the hour of the setting time

Pagina 6

14 LCD display: 13. Wireless Siren Coding Encryption Only the panel with built-in transmitter has this function. The signal used to code with

Pagina 7

15 In setup state, input the command: 45 + [XX] + # XX indicates: the delay time of alarm; XX= 01-99: 1 sec to 99 sec Note: The setting

Pagina 8

16 18. SMS Receiving Number Setting SMS Receiving number means when system is alarming, it will only send SMS to this mobile number. Yo

Pagina 9

17 keyboard operation. 21. Defense Zone Programming If you want to change the alarm attribute of defense zone, such as turn off the siren when

Pagina 10

18 defense zone number [01~99], then choose [Home Arm], and then choose whether alarm [0/1] button, and finally press [#] to confirm. The m

Pagina 11

19 24. Arm/ Disarm Siren Sound Setting After you activate this function, when you arm the system, the external siren will sound one short beep; a

Pagina 12

2 Contents Function Introduction Alarm Host Diagram Door Sensor Wireless PIR Detector Functions Settings I

Pagina 13

20 confirm; voice prompts: setting completed, please enter instruction. Operating method:【83】【A】【#】 A indicates: [1]: activate voice prompt for ar

Pagina 14

21 Users can use remote controller to set system as Out Arm, Home Arm, Emergency Alarm, Real-time Disarm and etc.  Out Arm: Press button 

Pagina 15

22 After the setting, the host makes a "Di" sound, ARM LED is on and you will receive a SMS: System armed. 5. Disarm It means to stop th

Pagina 16

23 If you answer the call, you will hear the pre-record voice. You can set system via your telephone or mobile phone keypad. If you hang-up d

Pagina 17

24 In disarm status, you can use the main unit to make any call just like a land-line telephone. Dial telephone number on keypad, press [ ] button,

Pagina 18

25 NO9 Zone: 19 Time: 11-06-25 11:45 (It indicates the first record: wireless zone 19 alarm time) 11. GSM Signal Checking Before installing the

Pagina 19

26 [Technical Parameters] List 1: Input Voltage DC12V/1A Standby Current <55mA Alarming Current <450mA Wireless Frequency 315/433MHz, PT22

Pagina 20

27 Siren sound time 180 sec. Home Appliance Optional [Components List] Main panel 1 pc, Remote controller

Pagina 21

28  Keep the alarm system dry. Rain, humidity and various fluids or moisture all will corrupt the electronic circuit.  Do not use or place the a

Pagina 22

29 other people remote control the system illegally.  Since the alarm system is continuously in operation or standby mode, the supply ada

Pagina 23

3 Components List Care and Maintenance [Function Instruction] 1. 7 wired and 99 wireless defense zones; 2. LCD screen with time

Pagina 24

30 Optional sensors/detectors are packed separately. You can choose according to your specific requirements.

Pagina 25

31 Operation Commands Function Description Remarks [Program Password] + [#] Enter settings Default password: 8888 [*] + [#] Exit settings [20]+[1

Pagina 26

32 [AA]: hour [BB]: minute [39] + [0/1] + [#] Timing Control: turn on/ off the function of timely arm/disarm 0: OFF 1: ON [41] + [

Pagina 27 - Optional

33 [1]SOS Alarm; [2] Fire Alarm; [3]Gas Leak Alarm; [4]Door Alarm; [5]Hall Alarm; [6]Window Alarm; [7]Balcony Alarm; [8]Boundary Alarm D:

Pagina 28

34 [Dial telephone number] +[ ] System Dialing Function [95175308246] + [#] Factory Reset Use with caution [operation password] + [1] Arm by SMS D

Pagina 29

4 concrete wall or fire door, etc. Alarm Panel front schematic diagram: Alarm Panel back schematic diagram: Wired terminal block:

Pagina 30

5 1 LB- Negative of speaker (black cable) 2 LB+ Positive of speaker (red cable) 3 GND Ground 4 Z1 Wired sensor 1: support both NO and NC 5 GND Grou

Pagina 31

6 3. Please pay attention to the siren connection. Do not mix the two cables together when connecting. Otherwise, it will damage the transistor in

Pagina 32

7  Magnet should be near to the side of transmitter with indicator. The two should align with each other and the distance should not exce

Pagina 33

8 Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as referen

Pagina 34

9 LCD display: 3. Exit Settings Press [*] and [#] buttons, the main unit emits a long beep and exits settings. The [SET] indicator